The Veris CW2 Protocol Series of air quality sensors for rooms is a flexible multi-sensor platform for use with BAS controllers designed to accept BACnet MSTP or Modbus outputs. CO2 and temperature sensors are included with all CW2 Protocol Series air quality sensors.
Product Applications
- Controlling ventilation in response to accuracy
- ASHRAE 62.1 compliant
- Office buildings, conference rooms, schools, retail stores, etc.
MANUALS (2)
4 in stock
Fast Shipping
Carrier information
20k products
Payment methods
24/7 Support
Unlimited help desk
2-day Delivery
Track or off orders
Product Highlights |
Mount: Wall ,Voltage: 20-30 VDC – 24 VAC ,Color: White ,Warranty: 5 Year Warranty |
---|---|
Specs |
Product Type: Sensor ,Application: Temperature ,Sensor Type: CO2 – Non-dispersive infrared (NDIR) – Transmitter Temperature Sensor ,Communication: BACnet MS/TP – Modbus ,Mount: Wall ,Operating Temp Range: 32° to 122°F ,Accuracy: ±30 ppm ±3% of reading – 1°F ,Range: 0-5000 ppm 0-2000 ppm ,Control Signal: 4 to 20 mA ,Output: 0 to (5 or 10) VDC ,Humidity Range: 0 to 95% RH (Non Condensing) ,AWG: 18-24 ,Housing Material: ABS Plastic ,Voltage: 20-30 VDC – 24 VAC ,Color: White ,Warranty: 5 Year |
Brand |
Veris |
Description
Related products
Eaton Freedom NEMA Pneumatic Timer, 10-180 Sec, 1NO/1NC, Top Mount
In stock
ICM103 Delay on Make Timer (1-1,023 Second Switch-Settable Delay)
In stock
Product Highlights |
Voltage : 18/240 VAC ,Amperage : 1 Amps ,Size : 2" x 2" |
---|---|
Specs |
Product Type: Delay on Make ,Time Delay: 1-1023 Sec Switch-Settable ,Voltage: 18/240 VAC ,Amperage: 1 ,Amp Inrush: 10 ,Holding Current: 40 mA ,Voltage Drop: 2.5v @1amp ,Size: 2" x 2" ,Replaces: 32394 – 3310-068 – TD3001A – TMF-19 – TMF-80 – 32396 – 7061 – 1C213 ,OEM: Ice-O-Matic – A-1 – Robertshaw – MARS – Supco |
Brand |
ICM Controls |
ICM492 Single Phase Motor Protection, 80-300 VAC
In stock
Product Highlights |
Voltage: 80/300 VAC ,Length (Inches): 3" Length ,Height: 1.35" |
---|---|
Specs |
Voltage: 80/300 VAC ,Frequency: 50-60 Hz ,Accuracy: +/- 2% ,Low Power Consumption: Max 50 mA @ 120V – Max 100 mA @ 240V ,Control Voltage: 24-240 VAC ,Output: Dry Relay Contacts (Type) – 10A resistive @ 277 VAC (NC contacts) – 10A resistive @ 277 VAC (NO contacts) ,Length (Inches): 3" ,Width: 3.2" ,Height: 1.35" |
Brand |
ICM Controls |