$134.82each
Description
The ICM2812-KIT is a universal replacement board that comes packaged with a series of cable harnesses that make it a replacement for the White-Rodgers 50M56U-843 and more than 150 competitive part numbers.
Product Features:
- Hot Surface Ignition (HSI) control board
- Microprocessor-based
- Monitors timing, trial for ignition, system switches, flame sensing and lockout.
- 100% lockout safety feature
- Compatible with LP or Natural Gas
- LED indication for status and fault codes to aid in troubleshooting
Product Specifications:
- Control voltage: 24 VAC (18-30 VAC)
- Line voltage: 120 VAC
- HSI Hot Surface Ignitor: 6 amp @ 120 VAC
- Gas Valve: 1.5 amp @ 24 VAC
- Inducer draft motor: 2.2 FLA @120 VAC
- Blower motor: 14.5 FLA @ 120 VAC
- Humidity Range: 5 to 95% relative humidity (non-condensing)
- White-Rodgers: 50M56U-843
MANUALS (2)
4 in stock
Fast Shipping
Carrier information
20k products
Payment methods
24/7 Support
Unlimited help desk
2-day Delivery
Track or off orders
Specs |
Product Type: Kit – Control Board ,Operating Temp Range: -40° to 176°F ,Control Voltage: 18-30 VAC ,Line Voltage: 120 VAC ,Humidity Range: 5% to 95% Relative Humidity (Non-Condensing) ,Heat Blower ON Delay: 30 Seconds ,Heat Blower OFF Delay: 100 Seconds – 150 Seconds ,Cool Blower ON Delay: 6 Seconds ,Cool Blower OFF Delay: 45 Seconds |
---|---|
Brand |
ICM Controls |
Description
Related products
ICM203F Delay on Break Timer, 6″ Wire Leads (.03-10 Minute Knob Adjust. Delay)
In stock
Product Highlights |
Voltage : 18/240 VAC ,Amperage : 1.5 Amps ,Size : 2" x 2" |
---|---|
Specs |
Product Type: Delay on Break ,Time Delay: 03-10 Min Knob Adjustable ,Wiring: 6" Wire Leads – 2 Wire ,Voltage: 18/240 VAC ,Amperage: 1.5 ,Amp Inrush: 15 ,Frequency: 50-60 Hz ,Voltage Drop: 3.5 V typical – 4.5 V maximum @ 1.5amps ,Holding Current: 40 mA (minimum) ,Size: 2" x 2" ,Replaces: TD73W – ADB-2 ,OEM: Supco – Wagner/DiversiTech |
Brand |
ICM Controls |
ICM401 Phase Loss and Reversal Protection, 190-600 VAC
In stock
ICM493 Line Voltage, Single Phase Motor Protection w/ Surge Protection, 60A contactor
In stock