$36.65each
Description
Controls the circulating fan in heat pump, air conditioning and forced air systems. Delay on make lets air reach proper level prior to turning on the fan. Off delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency.
Product Features
- Low cost open board design
- High power, relay output
- Dual function fan delay timer
- Controls the circulating fan in heat pump, A/C and forced air systems
- OFF delay purges ducts of residual air
- ON delay allows air to reach the proper comfort level prior to energizing the fan.
- Replaces thermal time delays
Mode of Operation – Power must be applied before and during the time delay period. When the initiate contact closes, the load energizes and remains energized as long as the initiate contact is closed. The time delay begins when the initiate contact opens. At the end of the time delay period, the load is turned off. If the initiate contact re-closes during the time delay period the load remains energized and the time delay is reset to zero. Removal of the input power during the delay turns off the load and resets the time delay to zero. A one second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering.
4 in stock
Fast Shipping
Carrier information
20k products
Payment methods
24/7 Support
Unlimited help desk
2-day Delivery
Track or off orders
Product Highlights |
Voltage: 18/30 VAC |
---|---|
Specs |
Frequency: 50-60 Hz – 50-60 Hz ,Voltage: 18/30 VAC ,– N.O.: 20 amps @ 240 VAC ,– N.C.: 20 amps @ 240 VAC ,Fixed Time Delay: 1 Second (ON) – 60 Seconds (OFF) ,Dimensions: 2.5" x 2.5" |
Brand |
ICM Controls |
Description
Related products
ICM203F Delay on Break Timer, 6″ Wire Leads (.03-10 Minute Knob Adjust. Delay)
In stock
Product Highlights |
Voltage : 18/240 VAC ,Amperage : 1.5 Amps ,Size : 2" x 2" |
---|---|
Specs |
Product Type: Delay on Break ,Time Delay: 03-10 Min Knob Adjustable ,Wiring: 6" Wire Leads – 2 Wire ,Voltage: 18/240 VAC ,Amperage: 1.5 ,Amp Inrush: 15 ,Frequency: 50-60 Hz ,Voltage Drop: 3.5 V typical – 4.5 V maximum @ 1.5amps ,Holding Current: 40 mA (minimum) ,Size: 2" x 2" ,Replaces: TD73W – ADB-2 ,OEM: Supco – Wagner/DiversiTech |
Brand |
ICM Controls |
ICM401 Phase Loss and Reversal Protection, 190-600 VAC
In stock
ICM493 Line Voltage, Single Phase Motor Protection w/ Surge Protection, 60A contactor
In stock
Remote Sensor for SimpleComfort and FrostSentry Thermostat
In stock
Reviews
Clear filtersThere are no reviews yet.